Machine Photos

Pharma and Lab - Laboratory - Waters - Maldi Synapt - Poland - Listing ID: 1220626

2008 Waters Maldi Synapt Laboratory for sale
2008 Waters Maldi Synapt Laboratory for sale — view 2
2008 Waters Maldi Synapt Laboratory for sale — view 3
2008 Waters Maldi Synapt Laboratory for sale
2008 Waters Maldi Synapt Laboratory for sale — view 2
2008 Waters Maldi Synapt Laboratory for sale — view 3

Currency Finance

Finance Solutions

Mortgage Choice

Equipment Finance

contact seller
Machineryline
https://machinelista.com/machine/waters-maldi-synapt-laboratory-equipment-for-sale/

2008 - Waters Maldi Synapt Laboratory Equipment

()
  • Listing No
  • 1220626
  • Year
  • 2008
  • Manufacturer
  • Waters
  • Model
  • Maldi Synapt
  • Condition
  • Used
  • Location
  • Poland
  • Price
  • $8,000
  • Description
  • The MALDI SYNAPT™ High Definition Mass Spectrometry™ (HDMS™) system is a double ionization device... The MALDI SYNAPT™ High Definition Mass Spectrometry™ (HDMS™) system is a dual ionization mass spectrometer that supports both MALDI and atmospheric pressure ionization (API), providing maximum analytical power for discovery research challenges. The system operates in time-of-flight (TOF) mode for accurate mass MALDI/MS and MS/MS experiments, and in ion mobility/TOF mode for ion mobility separation-based studies. The accurate MS and MS/MS capabilities of MALDI Synapt HDMS enable optimal results in proteomics, pharmaceutical and imaging experiments; IMS capabilities enable the separation of previously insoluble isobaric ions. Characteristics: 1. Triwave™ technology providing access to the unique benefits of ion mobility spectrometry (IMS) 2. Time-aligned parallel fragmentation (TAP) for first- and second-generation fragmentation structural information in one experiment 3. Fast, interchangeable MALDI/API sources 4. High load mode (HDC) providing increased sensitivity over a wide weight range 5. Integrates with the nanoACQUITY UPLC® system and the CTC PAL MALDI spot/fraction collector so you can perform off-line nanoscale separations with minimized sample complexity and dynamic range issues. Used, not tested. Please contact us.

About this machine

This Waters Maldi Synapt is a laboratory instrument — specifically a dual ionization mass spectrometer, sometimes referred to simply as a mass spec — designed for high-definition mass spectrometry analysis in demanding discovery research environments. Waters is a well-established scientific instrumentation company recognised for its analytical chemistry equipment, serving sectors such as pharmaceuticals, life sciences, and proteomics research.

The instrument supports both MALDI (Matrix-Assisted Laser Desorption/Ionization) and atmospheric pressure ionization (API) as interchangeable ionization sources, giving researchers the flexibility to switch between ionization modes depending on their analytical requirements. It operates in two primary modes: time-of-flight (TOF) mode for accurate mass MALDI/MS and MS/MS experiments, and ion mobility/TOF mode for ion mobility separation-based studies. This combination of capabilities makes the system well suited to proteomics, pharmaceutical analysis, and imaging experiments.

A key technological feature is Waters' proprietary Triwave technology, which provides access to ion mobility spectrometry (IMS). This enables the separation of isobaric ions — ions with the same nominal mass that would otherwise be indistinguishable — a capability that extends the analytical reach of the system beyond what conventional mass spectrometry alone can achieve. Complementing this is Time-Aligned Parallel (TAP) fragmentation, which captures both first- and second-generation fragmentation structural information within a single experiment, improving efficiency and depth of structural analysis.

The system also incorporates a High Definition Collision (HDC) high load mode, which increases sensitivity across a wide mass range. It is designed to integrate with the nanoACQUITY UPLC system and the CTC PAL MALDI spot/fraction collector, enabling off-line nanoscale separations that help manage sample complexity and dynamic range challenges.

This unit was manufactured in 2008, is offered in used condition from a seller located in Poland, and is listed at $8,000. It has not been tested prior to sale.

This description was generated automatically from the listing details and may not reflect every specification. Please confirm with the seller before purchase.

vaxim elan press

    Select

    Submitted

    Hi, thanks for your enquiry. We will reply to you soon.

    ERROR: Please fill out all the fields marked with an astericks (*)

      Select

      Select

      Submitted

      Hi, thanks for your enquiry. We will reply to you very soon.

      ERROR: Please fill out all the fields marked with an astericks (*)